CCL:G: G03 does not read pseudo



 Sent to CCL by: rafapa]|[us.es
 Dear Silvina,
 
the basis set and pseudopotential should be input in the following format.
 C O H 0
 6-311++G(d,p)
 ****
 Pt 0
 mwb 60
 ****
 Pt 0
 mwb 60
 
Only one blank line after the basis and no asterix after the pseudo just another blank line.
 Sincerely,
 Dr. Rafael R. Pappalardo
 Physical Chemistry Dept., Univ. de Sevilla (Spain)
 
On Sat, 4 Feb 2012 17:33:22 -0500, Silvina Bieza silvinabieza[*]gmail.com wrote:
 Sent to CCL by: "Silvina  Bieza" [silvinabieza^^gmail.com]
 Hello list,
 
I am experiencing some problems with a G03 calculation. This is my input:
 %chk=primero.chk
 #p b3lyp/genecp opt(maxcyc=100) scf(xqc,maxconventionalcyc=1000) freq
 Primero
 0 1
  Pt
  Pt                 1    2.60928411
  Pt                 1    2.60965373    2   63.48738392
 
Pt 1 2.59752708 2 60.15835847 3 -69.19506150 H 3 B1 1 A1 4 D1 C 3 B2 1 A2 4 D2 O 6 B3 3 A3 1 D3 H 7 B4 6 A4 3 D4 H 3 B5 1 A5 4 D5 H 6 B6 3 A6 1 D6
    B1             2.61248506
    B2             1.76404071
    B3             1.43000000
    B4             0.96000000
    B5             1.94502428
    B6             1.07000000
    A1            96.31367000
    A2            98.08570784
    A3           134.48029962
    A4           158.58000000
    A5           108.58589901
    A6            69.84936514
    D1           -20.04613476
    D2            -2.52843005
    D3           174.01972651
    D4          -103.92385498
    D5            29.78441690
    D6          -163.49304823
 C O H 0
 6-311++G(d,p)
 ****
 Pt 0
 mwb 60
 ****
 Pt 0
 mwb 60
 ****
 I believe that it is not reading the pseudopotential. When it reads
 the basis (from the output):
 General basis read from cards:  (5D, 7F)
  Centers:   6  7  5  8  9 10
  6-311++G(d,p)
  ****
  Centers:   1  2  3  4
  mwb60
  ****
 But then...
  1         78
                     2.680048 -1.455240  1.060615
                                    No pseudopotential on this center.
 And. This the warning I get in the output:
 
Warning! Pt atom 1 has 78 valence electrons but only 36 basis functions.
  This is less than a minimal basis set!
 I think there is something wrong in the input. Can you help me?
 Thank you very much,
 Silvina
 
-= This is automatically added to each message by the mailing script =- To recover the email address of the author of the message, please change> Conferences: http://server.ccl.net/chemistry/announcements/conferences/