CCL:G: [Fwd: W:Error with Frequency calculation when using genECP]



   --- the forwarded message follows ---
 
--- Begin Message ---
Your message was not distributed to CCL Subscribers.
 To send message to CCL subscribers you need to address it to
 chemistry^_^ccl.net or choose Subscribers on the CCL Web Mailing form.
 Jan
 ---------------------------- Original Message ----------------------------
 Subject: W:Error with Frequency calculation when using genECP
 > From:    "Don  Bunk" <bunk82^_^newpaltz.edu>
 Date:    Sat, November 19, 2005 4:36 pm
 To:      chemistry-request^_^ccl.net
 --------------------------------------------------------------------------
 Hey-
 I'm trying to run a 3-stage job with two optimizations, one with, one with
 out opt=Z-Matrix, and the third stage is a frequency calculation. It gets
 hung upon the Effective core potentials on the frequency calculation
 though. Any ideas?
 My input file is as follows:
 %chk=hist_CdSH3.chk
 %rwf=/scratch/hist_CdSH3.rwf
 %int=/scratch/hist_CdSH3.int
 %d2e=/scratch/hist_CdSH3.d2e
 %nproc=2
 %mem=2gb
  hf/genECP Opt=(NoEigen,Z-matrix,Maxcycle=999)
 Hist-CdSH3 hf Opt w/zm
 -2 1
 Cd1
 S2   1 R2
 H3   2 R3     1 A3
 S4   1 R4     2 A4    3 D4
 H5   4 R5     1 A5    2 D5
 S6   1 R6     2 A6    4 D6
 H7   6 R7     1 A7    4 D7
 N8   1 R8     2 A8    4 D8
 C9   8 R9     1 A9    4 D9
 C10  8 R10    1 A10   9 D10
 N11 10 R11    8 A11   9 D11
 C12 11 R12   10 A12   8 D12
 H13 10 R13   11 A13   8 D13
 H14 12 R14   11 A14   9 D14
 C15  9 R15    8 A15  12 D15
 H16 15 R16    9 A16   8 D16
 H17 15 R17    9 A17  16 D17
 C18 15 R18    9 A18  16 D18
 H19 18 R19   15 A19  16 D19
 N20 18 R20   15 A20  19 D20
 C21 18 R21   15 A21  19 D21
 H22 20 R22   18 A22  19 D22
 H23 20 R23   18 A23  22 D23
 O24 21 R24   18 A24  19 D24
 O25 21 R25   18 A25  24 D25
 H26 25 R26   21 A26  24 D26
 Variables:
  R2=2.65768
  R3=1.33454
  R4=2.65770
  R5=1.33454
  R6=2.65767
  R7=1.33454
  R8=2.65771
  R9=1.37591
  R10=1.35137
  R11=1.28719
  R12=1.37209
  R13=1.07087
  R14=1.07107
  R15=1.49560
  R16=1.08480
  R17=1.08422
  R18=1.54307
  R19=1.08579
  R20=1.45391
  R21=1.52926
  R22=1.00205
  R23=1.00184
  R24=1.18563
  R25=1.31873
  R26=0.95650
  A3=96.379
  A4=105.494
  A5=96.386
  A6=105.516
  A7=96.384
  A8=117.734
  A9=126.590
  A10=126.197
  A11=112.194
  A12=105.200
  A13=125.656
  A14=121.331
  A15=123.158
  A16=108.601
  A17=110.562
  A18=113.316
  A19=108.766
  A20=110.626
  A21=107.868
  A22=111.477
  A23=111.181
  A24=107.661
  A25=117.018
  A26=108.496
  D4=159.635
  D5=-34.094
  D6=-125.331
  D7=83.145
  D8=117.340
  D9=20.308
  D10=180.
  D11=0.531
  D12=-.0388
  D13=-179.993
  D14=-179.117
  D15=-178.898
  D16=-165.610
  D17=117.345
  D18=-121.060
  D19=-179.715
  D20=124.820
  D21=-114.463
  D22=-33.512
  D23=119.582
  D24=-40.216
  D25=-177.862
  D26=178.644
 C H O N S 0
 6-31g*
 ****
 Cd 0
 lanl2dz
 ****
 Cd 0
 lanl2
 --Link1--
 %chk=hist_CdSH3.chk
 %rwf=/scratch/hist_CdSH3.rwf
 %int=/scratch/hist_CdSH3.int
 %d2e=/scratch/hist_CdSH3.d2e
 %nproc=2
 %mem=2gb
  hf/genECP Geom=Check Opt=(NoEigen,MaxCycle=999)
 hist_Cd3 Optimization w/o ZM
 -2 1
 C H O N S 0
 6-31g*
 ****
 Cd 0
 lanl2dz
 ****
 Cd 0
 lanl2
 --Link1--
 %chk=hist_CdSH3.chk
 %rwf=/scratch/hist_CdSH3.rwf
 %int=/scratch/hist_CdSH3.int
 %d2e=/scratch/hist_CdSH3.d2e
 %nproc=2
 %mem=2gb
  hf/genECP Geom=Check Freq
 hist_Cd3 freq
 -2 1
 C H O N S 0
 6-31g*
 ****
 Cd 0
 lanl2dz
 ****
 Cd 0
 lanl2
 The job runs throught the first two opt's but then gives the following
 error on the frequency calculation:
  Rotational constants (GHZ):      0.4211850      0.2154773      0.1858423
  General basis read from cards:  (5D, 7F)
 
 ===================================================================================================================================
  Pseudopotential Parameters
 
 ===================================================================================================================================
   Center     Atomic      Valence      Angular      Power
                                     Coordinates
   Number     Number     Electrons     Momentum     of R      Exponent
   Coefficient                X           Y           Z
 
 ===================================================================================================================================
  EOF while reading ECP pointer card.
  Error termination via Lnk1e in /home/local/bin/gaussian/g03/l301.exe at
 Sat Nov 12 18:19:20 2005.
  Job cpu time:  0 days  0 hours  0 minutes  0.6 seconds.
  File lengths (MBytes):  RWF=     56 Int=      0 D2E=      0 Chk=     23 Scr=
 I don't understand it as the input for freq ECP is the exact same as the
 input for the other opt's that have no problem as far as I can tell. Any
 help would be greatly appreciated. Thanks. Cheers, Don Bunk