From owner-chemistry@ccl.net Wed Sep 6 08:25:00 2017 From: "Giuseppe Mallia g.mallia(~)imperial.ac.uk" To: CCL Subject: CCL:G: MSSC2017 - Ab initio Modelling in Solid State Chemistry - LAST CALL Message-Id: <-52971-170906073619-29994-w2VHyip38H3es961d9Inrw^server.ccl.net> X-Original-From: "Giuseppe Mallia" Date: Wed, 6 Sep 2017 07:36:17 -0400 Sent to CCL by: "Giuseppe Mallia" [g.mallia a imperial.ac.uk] This is the last call and if you register before Friday the 8th of September you will be added to the reduced fee list. ### MSSC2017 Ab initio Modelling in Solid State Chemistry Discovering quantum-mechanical simulations with CRYSTAL www.imperial.ac.uk/mssc2017 London Edition (New Users): London (UK), 18 - 22 September 2017 Directors: L. Bernasconi - N.M. Harrison - G. Mallia ### The Department of Chemistry and the Thomas Young Centre at Imperial College London and the Computational Materials Science Group of the Science and Technology Facilities Council (STFC), in collaboration with the Theoretical Chemistry Group of the University of Torino, are organizing the 2017 MSSC Summer School on the "ab initio modelling of crystalline and defective solids with the CRYSTAL code". The week long school is designed for new users of CRYSTAL, PhD students, Post-Docs and researchers with interests in solid state chemistry, physics, materials science, surface science, catalysis, magnetism and nano-science. It will provide an introduction to the capabilities of quantum mechanical simulations and to the practical use of CRYSTAL. CRYSTAL is a general-purpose program for the study of periodic solids. It uses a local basis set comprised of Gaussian type functions and can be used to perform calculations at the Hartree-Fock, density functional or global and range-separated hybrid functionals (e.g. B3LYP, HSE06), double hybrid levels of theory. Analytical first derivatives with respect to the nuclear coordinates and cell parameters and analytical derivatives, up to fourth order, with respect to an applied electric field (CPHF/CPKS) are available. The list of lecturers, registration details and general information can be found at the official School web site (see link above). From owner-chemistry@ccl.net Wed Sep 6 09:33:00 2017 From: "Carlos Simmerling carlos.simmerling:+:stonybrook.edu" To: CCL Subject: CCL: Oct 2 deadline for awards application, Computers in Chemistry Division Message-Id: <-52972-170906082907-1226-7dEOzJQdGKgvyo6QHzLjTg[A]server.ccl.net> X-Original-From: "Carlos Simmerling" Date: Wed, 6 Sep 2017 08:29:06 -0400 Sent to CCL by: "Carlos Simmerling" [carlos.simmerling+*+stonybrook.edu] Dear Students, PostDocs and Junior Faculty COMP Members: On behalf of the Division of Computers in Chemistry (COMP) of the American Chemical Society, we are soliciting nominations for the 2018 COMP awards for the Spring 2018 National American Chemical Society Meeting (March 18- 22 New Orleans, LA). Please note most of the awards have a October 2nd deadline. To find out more information about all COMP awards please visit our website http://www.acscomp.org CCG-sponsored award for grad students: http://www.acscomp.org/awards/chemical-computing-group-excellence-award Wiley-sponsored award for postdocs: http://www.acscomp.org/awards/the-comp-acs-outstanding-postdoc-award Openeye-sponsored outstanding junior faculty award: http://www.acscomp.org/awards/the-comp-acs-outstanding-junior-faculty- award Nvidia-sponsored GPU computing award: http://www.acscomp.org/awards/nvidia-gpu-award COMP also provides a select number of undergraduate poster awards at the meeting. No special application is needed other than the normal abstract submission to the ACS MAPS system. Application materials for many of these awards are due October 2nd! Please contact Carlos Simmerling if you have any questions. Prof. Carlos Simmerling Department of Chemistry Stony Brook University Stony Brook, NY 11794-3400 carlos.simmerling]*[stonybrook.edu From owner-chemistry@ccl.net Wed Sep 6 10:08:01 2017 From: "Igors Mihailovs igorsm^^^cfi.lu.lv" To: CCL Subject: CCL:G: Gaussian SCRF error "No solvent atoms in DisRep" Message-Id: <-52973-170906083843-4440-5w+s0xifrfNnE3Dm1cPUYw : server.ccl.net> X-Original-From: Igors Mihailovs Content-Language: en-US Content-Type: multipart/alternative; boundary="------------1F69AFCAB09F8256FBB13593" Date: Wed, 6 Sep 2017 15:41:00 +0300 MIME-Version: 1.0 Sent to CCL by: Igors Mihailovs [igorsm(0)cfi.lu.lv] This is a multi-part message in MIME format. --------------1F69AFCAB09F8256FBB13593 Content-Type: text/plain; charset=utf-8; format=flowed Content-Transfer-Encoding: 8bit Dear all, I got the answer from /Gaussian, Inc./, and it is below. Hello Igors, Thank you for giving us a chance to comment. The problem is that you have "Dis Rep Cav", which are non-electrostatic terms included in the G03 PCM models for the final energy. However, only limited number of solvents are defined (as in G03) and limited number of elements are available. For example, n,n-DiMethylFormamide is not available in G03. Please remove "Dis Rep Cav" and it should be fine. Lufeng Zou, Ph.D. Technical Support Gaussian, Inc. help++gaussian.com If we read between the lines, this probably means "please use *SMD* and not obsolete methods, if You care about non-electrostatic interactions". For me, the reason to use Dis Rep Cavwas so that I can use the low-cost CPCM instead of presumably high-cost IEFPCM mentioned as the basis for SMD in /G09 Reference/ (these considerations were based on previous experience by the senior lab staff). However, I did not manage to note that "SMD" is in fact "an option to PCM calculations", so now I did /p/-nitroaniline in DCM solution with SCRF=(CPCM,SMD,Solvent=…), as well as withSCRF=(IEFPCM,SMD,Solvent=…), with the following results: 1. Both route sections did not bring about any errors 2. IEFPCM calculation actually lasted almost a minute less than CPCM one (2:7 vs. 2:53 minutes). 3. Error on polarization charges was 0.016 for IEFPCM and 0.306 for CPCM. So now I at least understand why CPCM is not suggested by /Gaussian, Inc./ staff. Thanks to Dr. Zou for the comment and to Zhiqiang Zhang for raising the issue! With best regards, Igors Mihailovs ISSP UL On 03/09/17 19:16, Igors Mihailovs igorsm|*|cfi.lu.lv wrote: > Dear all, > > I have encountered the same problem when trying to use DMFA with > SCRF=Read (in my case, also Dis Rep, along with Cav and Surface=SAS). > Also /Gaussian 09/, rev. D.01. It seems to me that N,N-DMFA is not > completely defined in this version? I postponed writing to > /Gaussian//, //Inc./, but I will do it now as other people have the > same issue, if nobody reports here today. > > Using the following non-standard input for PCM: > Surface=SAS Dis Rep Cav NonEq=Write RSolv=2.647 > --- end of non-standard input. > ------------------------------------------------------------------------------ > Polarizable Continuum Model (PCM) > ================================= > Model : C-PCM. > Atomic radii : UFF (Universal Force Field). > Polarization charges : Total charges. > Charge compensation : None. > Solution method : On-the-fly selection. > Cavity type : SAS (Solvent Accessible Surface) (Alpha=1.000). > Cavity algorithm : GePol (No added spheres) > Default sphere list used, NSphG= 52. > Lebedev-Laikov grids with approx. 5.0 points / > Ang**2. > Smoothing algorithm: Karplus/York (Gamma=1.0000). > Polarization charges: spherical gaussians, with > point-specific exponents > (IZeta= 3). > Self-potential: point-specific (ISelfS= 7). > Self-field : sphere-specific E.n sum rule > (ISelfD= 2). > Solvent : n,n-DiMethylFormamide, Eps= 37.219000 > Eps(inf)= 2.046330 > RSolv= 2.647000 Ang. > ------------------------------------------------------------------------------ > Warning! Inconsistent VMol and RSolv for this solvent, using VMol= > 77.69 Ang**3. > No solvent atoms in DisRep. > Error termination via Lnk1e in /home/igors/g09/l301.exe at Wed May 24 > 20:48:59 2017. > Job cpu time: 0 days 0 hours 0 minutes 8.5 seconds. > File lengths (MBytes): RWF= 610 Int= 0 D2E= 0 Chk= > 25 Scr= 1 > > If there is no manual definitionof RSolv, the following is printed: > > Solvent : n,n-DiMethylFormamide, Eps= 37.219000 > Eps(inf)= 2.046330 > RSolv= 0.000000 Ang. > ------------------------------------------------------------------------------ > Warning! Inconsistent VMol and RSolv for this solvent, using VMol= > 0.00 Ang**3. > No solvent atoms in DisRep. > Error termination via Lnk1e in /home/igors/g09/l301.exe at Fri May 19 > 02:16:27 2017 > > With best regards, > Igors Mihailovs > ISSP UL > > On 03/09/17 01:37, Zhiqiang Zhang zhangzq/./udel.edu wrote: >> Sent to CCL by: "Zhiqiang Zhang" [zhangzq{=}udel.edu] >> Hi all, >> I am doing calculation with solvent and get the error "No solvent atoms in DisRep" at the end. I am trying >> to include the dispersion and repulsion correction in my calculation. >> My input file: >> >> # opt() freq m062x/6-311G(2df,p) SCRF(CPCM, solvent=AceticAcid, read) >> >> Title Card Required >> >> 0 1 >> O 0.00000000 0.00000000 0.11813800 >> H 0.00000000 0.75681000 -0.47255200 >> H 0.00000000 -0.75681000 -0.47255200 >> >> dis >> rep >> cav >> >> /*End of my input file*/ >> The last two lines of the log files: >> No solvent atoms in DisRep. >> Error termination via Lnk1e in /opt/shared/gaussian/g09d01/g09/l301.exe at Sat Sep 2 17:24:24 2017. >> >> Does anybody know how to resolve this issue? >> --------------1F69AFCAB09F8256FBB13593 Content-Type: text/html; charset=utf-8 Content-Transfer-Encoding: 8bit Dear all,

I got the answer from Gaussian, Inc., and it is below.

Hello Igors,
Thank you for giving us a chance to comment.

The problem is that you have "Dis Rep Cav", which are non-electrostatic terms included in the G03 PCM models for the final energy. However, only limited number of solvents are defined (as in G03) and limited number of elements are available. For example, n,n-DiMethylFormamide is not available in G03.

Please remove "Dis Rep Cav" and it should be fine.
Lufeng Zou, Ph.D.
Technical Support
Gaussian, Inc.
help++gaussian.com
If we read between the lines, this probably means "please use SMD and not obsolete methods, if You care about non-electrostatic interactions".
For me, the reason to use
Dis Rep Cav was so that I can use the low-cost CPCM instead of presumably high-cost IEFPCM mentioned as the basis for SMD in G09 Reference (these considerations were based on previous experience by the senior lab staff). However, I did not manage to note that "SMD" is in fact "an option to PCM calculations", so now I did p-nitroaniline in DCM solution with SCRF=(CPCM,SMD,Solvent=…), as well as with SCRF=(IEFPCM,SMD,Solvent=…), with the following results:
1. Both route sections did not bring about any errors
2. IEFPCM calculation actually lasted almost a minute less than CPCM one (2:7 vs. 2:53 minutes).
3. Error on polarization charges was 0.016 for IEFPCM and 0.306 for CPCM.

So now I at least understand why CPCM is not suggested by Gaussian, Inc. staff. Thanks to Dr. Zou for the comment and to

Zhiqiang Zhang for raising the issue!

With best regards,

Igors Mihailovs
ISSP UL


On 03/09/17 19:16, Igors Mihailovs igorsm|*|cfi.lu.lv wrote:
Dear all,

I have encountered the same problem when trying to use DMFA with SCRF=Read (in my case, also Dis Rep, along with Cav and Surface=SAS). Also Gaussian 09, rev. D.01. It seems to me that N,N-DMFA is not completely defined in this version? I postponed writing to Gaussian, Inc., but I will do it now as other people have the same issue, if nobody reports here today.

Using the following non-standard input for PCM:
 Surface=SAS Dis Rep Cav NonEq=Write RSolv=2.647
 --- end of non-standard input.
 ------------------------------------------------------------------------------
 Polarizable Continuum Model (PCM)
 =================================
 Model                : C-PCM.
 Atomic radii         : UFF (Universal Force Field).
 Polarization charges : Total charges.
 Charge compensation  : None.
 Solution method      : On-the-fly selection.
 Cavity type          : SAS (Solvent Accessible Surface) (Alpha=1.000).
 Cavity algorithm     : GePol (No added spheres)
                        Default sphere list used, NSphG=   52.
                        Lebedev-Laikov grids with approx.  5.0 points / Ang**2.
                        Smoothing algorithm: Karplus/York (Gamma=1.0000).
                        Polarization charges: spherical gaussians, with
                                              point-specific exponents (IZeta= 3).
                        Self-potential: point-specific (ISelfS= 7).
                        Self-field    : sphere-specific E.n sum rule (ISelfD= 2).
 Solvent              : n,n-DiMethylFormamide, Eps=  37.219000 Eps(inf)=   2.046330
                        RSolv=   2.647000 Ang.
 ------------------------------------------------------------------------------
 Warning! Inconsistent VMol and RSolv for this solvent, using VMol=   77.69 Ang**3.
 No solvent atoms in DisRep.
 Error termination via Lnk1e in /home/igors/g09/l301.exe at Wed May 24 20:48:59 2017.
 Job cpu time:       0 days  0 hours  0 minutes  8.5 seconds.
 File lengths (MBytes):  RWF=    610 Int=      0 D2E=      0 Chk=     25 Scr=      1


If there is no manual definition
of RSolv, the following is printed:

Solvent              : n,n-DiMethylFormamide, Eps=  37.219000 Eps(inf)=   2.046330
                        RSolv=   0.000000 Ang.
 ------------------------------------------------------------------------------
 Warning! Inconsistent VMol and RSolv for this solvent, using VMol=    0.00 Ang**3.
 No solvent atoms in DisRep.
 Error termination via Lnk1e in /home/igors/g09/l301.exe at Fri May 19 02:16:27 2017


With best regards,
Igors Mihailovs
ISSP UL


On 03/09/17 01:37, Zhiqiang Zhang zhangzq/./udel.edu wrote:
Sent to CCL by: "Zhiqiang  Zhang" [zhangzq{=}udel.edu]
Hi all,
I am doing calculation with solvent and get the error "No solvent atoms in DisRep" at the end. I am trying 
to include the dispersion and repulsion correction in my calculation.
My input file:

# opt() freq m062x/6-311G(2df,p) SCRF(CPCM, solvent=AceticAcid, read)

Title Card Required

0 1
 O                  0.00000000    0.00000000    0.11813800
 H                  0.00000000    0.75681000   -0.47255200
 H                  0.00000000   -0.75681000   -0.47255200

dis
rep
cav

/*End of my input file*/
The last two lines of the log files:
No solvent atoms in DisRep.
 Error termination via Lnk1e in /opt/shared/gaussian/g09d01/g09/l301.exe at Sat Sep  2 17:24:24 2017.

Does anybody know how to resolve this issue?

--------------1F69AFCAB09F8256FBB13593-- From owner-chemistry@ccl.net Wed Sep 6 17:49:00 2017 From: "Zhiqiang Zhang zqzhang2101-$-gmail.com" To: CCL Subject: CCL:G: Gaussian SCRF error "No solvent atoms in DisRep" Message-Id: <-52974-170906164539-16174-uMiKdLrfvHsri3Zq8xG7TQ---server.ccl.net> X-Original-From: Zhiqiang Zhang Content-Type: multipart/alternative; boundary="_5E5868C6-B423-46B7-8DD1-08A63F058AB3_" Date: Wed, 6 Sep 2017 16:45:32 -0400 MIME-Version: 1.0 Sent to CCL by: Zhiqiang Zhang [zqzhang2101]~[gmail.com] --_5E5868C6-B423-46B7-8DD1-08A63F058AB3_ Content-Transfer-Encoding: base64 Content-Type: text/plain; charset="utf-8" SGkgSWdvcnMsDQoNClRoYW5rIHlvdSBmb3Igc2hhcmluZyB0aGlzIGNvbW1lbnQuIEluIG15IHVu ZGVyc3RhbmRpbmcsIHRoZSBjb21tZW50IGZyb20gR2F1c3NpYW4sIEluYy4gc3RhZmYgbWVhbnMg bm90IGFsbCB0aGUgc29sdmVudHMgYXZhaWxhYmxlIGluIHRoZWlyIGRhdGFiYXNlIChsaWtlIG4s bi1EaU1ldGh5bEZvcm1hbWlkZSBpbiB5b3VyIGNhc2UpIGFyZSBkZWZpbmVkIGZvciDigJxEaXMg UmVwIENhduKAnSBjYWxjdWxhdGlvbi4gVGhpcyBpcyBpbmZvcm1hdGlvbiBpcyBub3QgdmVyeSBj bGVhciBpbiB0aGUgRzA5IG1hbnVhbCBvbiB0aGVpciB3ZWJzaXRlLiBNYXliZSB0aGlzIGlzIGFu IG9ic29sZXRlIG1ldGhvZCBhcyB5b3UgbWVudGlvbmVkIGFuZCB3ZSBjYW4gdXNlIFNNRCB0byBn ZXQgdGhlIHJlc3VsdHMuDQoNCkJlc3QsDQpaaGlxaWFuZyAgWmhhbmcNCg0KRnJvbTogSWdvcnMg TWloYWlsb3ZzIGlnb3JzbV5eXmNmaS5sdS5sdg0KU2VudDogV2VkbmVzZGF5LCBTZXB0ZW1iZXIg NiwgMjAxNyAxMjowNyBQTQ0KVG86IFpoYW5nLCBaaGlxaWFuZyAtaWQjemEtDQpTdWJqZWN0OiBD Q0w6RzogR2F1c3NpYW4gU0NSRiBlcnJvciAiTm8gc29sdmVudCBhdG9tcyBpbiBEaXNSZXAiDQoN CkRlYXIgYWxsLA0KDQpJIGdvdCB0aGUgYW5zd2VyIGZyb20gR2F1c3NpYW4sIEluYy4sIGFuZCBp dCBpcyBiZWxvdy4NCkhlbGxvIElnb3JzLA0KVGhhbmsgeW91IGZvciBnaXZpbmcgdXMgYSBjaGFu Y2UgdG8gY29tbWVudC4NCg0KVGhlIHByb2JsZW0gaXMgdGhhdCB5b3UgaGF2ZSAiRGlzIFJlcCBD YXYiLCB3aGljaCBhcmUgbm9uLWVsZWN0cm9zdGF0aWMgdGVybXMgaW5jbHVkZWQgaW4gdGhlIEcw MyBQQ00gbW9kZWxzIGZvciB0aGUgZmluYWwgZW5lcmd5LiBIb3dldmVyLCBvbmx5IGxpbWl0ZWQg bnVtYmVyIG9mIHNvbHZlbnRzIGFyZSBkZWZpbmVkIChhcyBpbiBHMDMpIGFuZCBsaW1pdGVkIG51 bWJlciBvZiBlbGVtZW50cyBhcmUgYXZhaWxhYmxlLiBGb3IgZXhhbXBsZSwgbixuLURpTWV0aHls Rm9ybWFtaWRlIGlzIG5vdCBhdmFpbGFibGUgaW4gRzAzLiANCg0KUGxlYXNlIHJlbW92ZSAiRGlz IFJlcCBDYXYiIGFuZCBpdCBzaG91bGQgYmUgZmluZS4NCg0KTHVmZW5nIFpvdSwgUGguRC4NClRl Y2huaWNhbCBTdXBwb3J0DQpHYXVzc2lhbiwgSW5jLg0KaGVscCwsZ2F1c3NpYW4uY29tDQpJZiB3 ZSByZWFkIGJldHdlZW4gdGhlIGxpbmVzLCB0aGlzIHByb2JhYmx5IG1lYW5zICJwbGVhc2UgdXNl IFNNRCBhbmQgbm90IG9ic29sZXRlIG1ldGhvZHMsIGlmIFlvdSBjYXJlIGFib3V0IG5vbi1lbGVj dHJvc3RhdGljIGludGVyYWN0aW9ucyIuDQpGb3IgbWUsIHRoZSByZWFzb24gdG8gdXNlIERpcyBS ZXAgQ2F2IHdhcyBzbyB0aGF0IEkgY2FuIHVzZSB0aGUgbG93LWNvc3QgQ1BDTSBpbnN0ZWFkIG9m IHByZXN1bWFibHkgaGlnaC1jb3N0IElFRlBDTSBtZW50aW9uZWQgYXMgdGhlIGJhc2lzIGZvciBT TUQgaW4gRzA5IFJlZmVyZW5jZSAodGhlc2UgY29uc2lkZXJhdGlvbnMgd2VyZSBiYXNlZCBvbiBw cmV2aW91cyBleHBlcmllbmNlIGJ5IHRoZSBzZW5pb3IgbGFiIHN0YWZmKS4gSG93ZXZlciwgSSBk aWQgbm90IG1hbmFnZSB0byBub3RlIHRoYXQgIlNNRCIgaXMgaW4gZmFjdCAiYW4gb3B0aW9uIHRv IFBDTSBjYWxjdWxhdGlvbnMiLCBzbyBub3cgSSBkaWQgcC1uaXRyb2FuaWxpbmUgaW4gRENNIHNv bHV0aW9uIHdpdGggU0NSRj0oQ1BDTSxTTUQsU29sdmVudD3igKYpLCBhcyB3ZWxsIGFzIHdpdGgg U0NSRj0oSUVGUENNLFNNRCxTb2x2ZW50PeKApiksIHdpdGggdGhlIGZvbGxvd2luZyByZXN1bHRz Og0KMS4gQm90aCByb3V0ZSBzZWN0aW9ucyBkaWQgbm90IGJyaW5nIGFib3V0IGFueSBlcnJvcnMN CjIuIElFRlBDTSBjYWxjdWxhdGlvbiBhY3R1YWxseSBsYXN0ZWQgYWxtb3N0IGEgbWludXRlIGxl c3MgdGhhbiBDUENNIG9uZSAoMjo3IHZzLiAyOjUzIG1pbnV0ZXMpLg0KMy4gRXJyb3Igb24gcG9s YXJpemF0aW9uIGNoYXJnZXMgd2FzIDAuMDE2IGZvciBJRUZQQ00gYW5kIDAuMzA2IGZvciBDUENN Lg0KDQpTbyBub3cgSSBhdCBsZWFzdCB1bmRlcnN0YW5kIHdoeSBDUENNIGlzIG5vdCBzdWdnZXN0 ZWQgYnkgR2F1c3NpYW4sIEluYy4gc3RhZmYuIFRoYW5rcyB0byBEci4gWm91IGZvciB0aGUgY29t bWVudCBhbmQgdG8gDQpaaGlxaWFuZyBaaGFuZyBmb3IgcmFpc2luZyB0aGUgaXNzdWUhDQoNCldp dGggYmVzdCByZWdhcmRzLA0KSWdvcnMgTWloYWlsb3ZzDQpJU1NQIFVMDQpPbiAwMy8wOS8xNyAx OToxNiwgSWdvcnMgTWloYWlsb3ZzIGlnb3JzbXwqfGNmaS5sdS5sdiB3cm90ZToNCkRlYXIgYWxs LA0KDQpJIGhhdmUgZW5jb3VudGVyZWQgdGhlIHNhbWUgcHJvYmxlbSB3aGVuIHRyeWluZyB0byB1 c2UgRE1GQSB3aXRoIFNDUkY9UmVhZCAoaW4gbXkgY2FzZSwgYWxzbyBEaXMgUmVwLCBhbG9uZyB3 aXRoIENhdiBhbmQgU3VyZmFjZT1TQVMpLiBBbHNvIEdhdXNzaWFuIDA5LCByZXYuIEQuMDEuIEl0 IHNlZW1zIHRvIG1lIHRoYXQgTixOLURNRkEgaXMgbm90IGNvbXBsZXRlbHkgZGVmaW5lZCBpbiB0 aGlzIHZlcnNpb24/IEkgcG9zdHBvbmVkIHdyaXRpbmcgdG8gR2F1c3NpYW4sIEluYy4sIGJ1dCBJ IHdpbGwgZG8gaXQgbm93IGFzIG90aGVyIHBlb3BsZSBoYXZlIHRoZSBzYW1lIGlzc3VlLCBpZiBu b2JvZHkgcmVwb3J0cyBoZXJlIHRvZGF5Lg0KDQpVc2luZyB0aGUgZm9sbG93aW5nIG5vbi1zdGFu ZGFyZCBpbnB1dCBmb3IgUENNOg0KwqBTdXJmYWNlPVNBUyBEaXMgUmVwIENhdiBOb25FcT1Xcml0 ZSBSU29sdj0yLjY0Nw0KwqAtLS0gZW5kIG9mIG5vbi1zdGFuZGFyZCBpbnB1dC4NCsKgLS0tLS0t LS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0t LS0tLS0tLS0tLS0tLS0tDQrCoFBvbGFyaXphYmxlIENvbnRpbnV1bSBNb2RlbCAoUENNKQ0KwqA9 PT09PT09PT09PT09PT09PT09PT09PT09PT09PT09PT0NCsKgTW9kZWzCoMKgwqDCoMKgwqDCoMKg wqDCoMKgwqDCoMKgwqAgOiBDLVBDTS4NCsKgQXRvbWljIHJhZGlpwqDCoMKgwqDCoMKgwqDCoCA6 IFVGRiAoVW5pdmVyc2FsIEZvcmNlIEZpZWxkKS4NCsKgUG9sYXJpemF0aW9uIGNoYXJnZXMgOiBU b3RhbCBjaGFyZ2VzLg0KwqBDaGFyZ2UgY29tcGVuc2F0aW9uwqAgOiBOb25lLg0KwqBTb2x1dGlv biBtZXRob2TCoMKgwqDCoMKgIDogT24tdGhlLWZseSBzZWxlY3Rpb24uDQrCoENhdml0eSB0eXBl wqDCoMKgwqDCoMKgwqDCoMKgIDogU0FTIChTb2x2ZW50IEFjY2Vzc2libGUgU3VyZmFjZSkgKEFs cGhhPTEuMDAwKS4NCsKgQ2F2aXR5IGFsZ29yaXRobcKgwqDCoMKgIDogR2VQb2wgKE5vIGFkZGVk IHNwaGVyZXMpDQrCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKg IERlZmF1bHQgc3BoZXJlIGxpc3QgdXNlZCwgTlNwaEc9wqDCoCA1Mi4NCsKgwqDCoMKgwqDCoMKg wqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqAgTGViZWRldi1MYWlrb3YgZ3JpZHMgd2l0 aCBhcHByb3guwqAgNS4wIHBvaW50cyAvIEFuZyoqMi4NCsKgwqDCoMKgwqDCoMKgwqDCoMKgwqDC oMKgwqDCoMKgwqDCoMKgwqDCoMKgwqAgU21vb3RoaW5nIGFsZ29yaXRobTogS2FycGx1cy9Zb3Jr IChHYW1tYT0xLjAwMDApLg0KwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDC oMKgwqDCoCBQb2xhcml6YXRpb24gY2hhcmdlczogc3BoZXJpY2FsIGdhdXNzaWFucywgd2l0aA0K wqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDC oMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgIHBvaW50LXNwZWNpZmljIGV4cG9uZW50 cyAoSVpldGE9IDMpLg0KwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKg wqDCoCBTZWxmLXBvdGVudGlhbDogcG9pbnQtc3BlY2lmaWMgKElTZWxmUz0gNykuDQrCoMKgwqDC oMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgIFNlbGYtZmllbGTCoMKgwqAg OiBzcGhlcmUtc3BlY2lmaWMgRS5uIHN1bSBydWxlIChJU2VsZkQ9IDIpLg0KwqBTb2x2ZW50wqDC oMKgwqDCoMKgwqDCoMKgwqDCoMKgwqAgOiBuLG4tRGlNZXRoeWxGb3JtYW1pZGUsIEVwcz3CoCAz Ny4yMTkwMDAgRXBzKGluZik9wqDCoCAyLjA0NjMzMA0KwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKg wqDCoMKgwqDCoMKgwqDCoMKgwqDCoCBSU29sdj3CoMKgIDIuNjQ3MDAwIEFuZy4NCsKgLS0tLS0t LS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0t LS0tLS0tLS0tLS0tLS0tDQrCoFdhcm5pbmchIEluY29uc2lzdGVudCBWTW9sIGFuZCBSU29sdiBm b3IgdGhpcyBzb2x2ZW50LCB1c2luZyBWTW9sPcKgwqAgNzcuNjkgQW5nKiozLg0KwqBObyBzb2x2 ZW50IGF0b21zIGluIERpc1JlcC4NCsKgRXJyb3IgdGVybWluYXRpb24gdmlhIExuazFlIGluIC9o b21lL2lnb3JzL2cwOS9sMzAxLmV4ZSBhdCBXZWQgTWF5IDI0IDIwOjQ4OjU5IDIwMTcuDQrCoEpv YiBjcHUgdGltZTrCoMKgwqDCoMKgwqAgMCBkYXlzwqAgMCBob3Vyc8KgIDAgbWludXRlc8KgIDgu NSBzZWNvbmRzLg0KwqBGaWxlIGxlbmd0aHMgKE1CeXRlcyk6wqAgUldGPcKgwqDCoCA2MTAgSW50 PcKgwqDCoMKgwqAgMCBEMkU9wqDCoMKgwqDCoCAwIENoaz3CoMKgwqDCoCAyNSBTY3I9wqDCoMKg wqDCoCAxDQoNCklmIHRoZXJlIGlzIG5vIG1hbnVhbCBkZWZpbml0aW9uIG9mIFJTb2x2LCB0aGUg Zm9sbG93aW5nIGlzIHByaW50ZWQ6DQoNClNvbHZlbnTCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDC oCA6IG4sbi1EaU1ldGh5bEZvcm1hbWlkZSwgRXBzPcKgIDM3LjIxOTAwMCBFcHMoaW5mKT3CoMKg IDIuMDQ2MzMwDQrCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKgwqDCoMKg IFJTb2x2PcKgwqAgMC4wMDAwMDAgQW5nLg0KwqAtLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0t LS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0tLS0NCsKgV2Fy bmluZyEgSW5jb25zaXN0ZW50IFZNb2wgYW5kIFJTb2x2IGZvciB0aGlzIHNvbHZlbnQsIHVzaW5n IFZNb2w9wqDCoMKgIDAuMDAgQW5nKiozLg0KwqBObyBzb2x2ZW50IGF0b21zIGluIERpc1JlcC4N CsKgRXJyb3IgdGVybWluYXRpb24gdmlhIExuazFlIGluIC9ob21lL2lnb3JzL2cwOS9sMzAxLmV4 ZSBhdCBGcmkgTWF5IDE5IDAyOjE2OjI3IDIwMTcNCldpdGggYmVzdCByZWdhcmRzLA0KSWdvcnMg TWloYWlsb3ZzDQpJU1NQIFVMDQoNCk9uIDAzLzA5LzE3IDAxOjM3LCBaaGlxaWFuZyBaaGFuZyB6 aGFuZ3pxLy4vdWRlbC5lZHUgd3JvdGU6DQpTZW50IHRvIENDTCBieTogIlpoaXFpYW5nICBaaGFu ZyIgW3poYW5nenF7PX11ZGVsLmVkdV0NCkhpIGFsbCwNCkkgYW0gZG9pbmcgY2FsY3VsYXRpb24g d2l0aCBzb2x2ZW50IGFuZCBnZXQgdGhlIGVycm9yICJObyBzb2x2ZW50IGF0b21zIGluIERpc1Jl cCIgYXQgdGhlIGVuZC4gSSBhbSB0cnlpbmcgDQp0byBpbmNsdWRlIHRoZSBkaXNwZXJzaW9uIGFu ZCByZXB1bHNpb24gY29ycmVjdGlvbiBpbiBteSBjYWxjdWxhdGlvbi4NCk15IGlucHV0IGZpbGU6 DQoNCiMgb3B0KCkgZnJlcSBtMDYyeC82LTMxMUcoMmRmLHApIFNDUkYoQ1BDTSwgc29sdmVudD1B Y2V0aWNBY2lkLCByZWFkKQ0KDQpUaXRsZSBDYXJkIFJlcXVpcmVkDQoNCjAgMQ0KIE8gICAgICAg ICAgICAgICAgICAwLjAwMDAwMDAwICAgIDAuMDAwMDAwMDAgICAgMC4xMTgxMzgwMA0KIEggICAg ICAgICAgICAgICAgICAwLjAwMDAwMDAwICAgIDAuNzU2ODEwMDAgICAtMC40NzI1NTIwMA0KIEgg ICAgICAgICAgICAgICAgICAwLjAwMDAwMDAwICAgLTAuNzU2ODEwMDAgICAtMC40NzI1NTIwMA0K DQpkaXMNCnJlcA0KY2F2DQoNCi8qRW5kIG9mIG15IGlucHV0IGZpbGUqLw0KVGhlIGxhc3QgdHdv IGxpbmVzIG9mIHRoZSBsb2cgZmlsZXM6DQpObyBzb2x2ZW50IGF0b21zIGluIERpc1JlcC4NCiBF cnJvciB0ZXJtaW5hdGlvbiB2aWEgTG5rMWUgaW4gL29wdC9zaGFyZWQvZ2F1c3NpYW4vZzA5ZDAx L2cwOS9sMzAxLmV4ZSBhdCBTYXQgU2VwICAyIDE3OjI0OjI0IDIwMTcuDQoNCkRvZXMgYW55Ym9k eSBrbm93IGhvdyB0byByZXNvbHZlIHRoaXMgaXNzdWU/DQoNCg0KDQoNCi0tLQ0KVGhpcyBlbWFp bCBoYXMgYmVlbiBjaGVja2VkIGZvciB2aXJ1c2VzIGJ5IEF2YXN0IGFudGl2aXJ1cyBzb2Z0d2Fy ZS4NCmh0dHBzOi8vd3d3LmF2YXN0LmNvbS9hbnRpdmlydXMNCg== --_5E5868C6-B423-46B7-8DD1-08A63F058AB3_ Content-Transfer-Encoding: quoted-printable Content-Type: text/html; charset="utf-8"

Hi Igors,

 

Thank you for sharing this comment.= In my understanding, the comment from Gaussian, Inc. staff means not all t= he solvents available in their database (like n,n-DiMethylFormamide in your= case) are defined for =E2=80=9CDis Rep Cav=E2=80=9D calculation. This is i= nformation is not very clear in the G09 manual on their website. Maybe this= is an obsolete method as you mentioned and we can use SMD to get the resul= ts.

 

Best,=

Zhiqiang =C2=A0Zhang

=  

From: Igors Mihailovs igorsm^^^cfi.lu.lv
Sent: Wednes= day, September 6, 2017 12:07 PM
To: Zhang, Zhiqiang
Subject: CCL:G: Gaussian = SCRF error "No solvent atoms in DisRep"

 

Dear all,

I got the answer from Gaussian,= Inc., and it is below.

Hello Igors,
Thank you for giving us a chance to comment.=

The prob= lem is that you have "Dis Rep Cav", which are non-electrostatic t= erms included in the G03 PCM models for the final energy. However, only lim= ited number of solvents are defined (as in G03) and limited number of eleme= nts are available. For example, n,n-DiMethylFormamide is not available in G= 03.

Plea= se remove "Dis Rep Cav" and it should be fine.

Lufeng Zou, Ph.D.
Technical Support
Gau=
ssian, Inc.
help,,gaussian.com

If= we read between the lines, this probably means "please use SMD= and not obsolete methods, if You care about non-electrostatic interactions= ".
For me, the reason to use
Dis Rep Cav was so that I can use the low-cost CPCM instead of presumably high= -cost IEFPCM mentioned as the basis for SMD in G09 Reference (these = considerations were based on previous experience by the senior lab staff). = However, I did not manage to note that "SMD" is in fact "an option to PCM calculations&= quot;, so now I did p-nitroaniline in DCM solution with <= span style=3D'font-size:10.0pt'>SCRF=3D(CPCM,SMD,Solvent=3D=E2=80=A6), as well as with= SCRF=3D(IEFPCM,SMD,Solvent=3D= =E2=80=A6),= with the following results:
1. Both route sections did not bring about = any errors
2. IEFPCM calculation actually lasted almost a minute less th= an CPCM one (2:7 vs. 2:53 minutes).
3. Error on polarization charges was= 0.016 for IEFPCM and 0.306 for CPCM.

So now I at least understand w= hy CPCM is not suggested by Gaussian, Inc. staff. Thanks to Dr. Zou = for the comment and to

Zhiqiang Zhang for raising the issue!

With best regards,<= /span>
Igors Mihailo= vs
ISSP UL

On 03/09/17 19= :16, Igors Mihailovs igorsm|*|cfi.lu.lv wrote:

Dear all,


I have encountered the same pr= oblem when trying to use
DMFA with SCRF=3DRead (in my case, also Dis Rep, along with Cav and Surface=3DSAS). Also Gaussian 09, rev. D.01. It se= ems to me that N,N-DMFA is not completely defined in this version? I postpo= ned writing to Gaussian, Inc., but I will do it now as other people = have the same issue, if nobody reports here today.

Using the follow= ing non-standard input for PCM:
 Surface=3DSAS Dis Rep Cav NonEq=3D= Write RSolv=3D2.647
 --- end of non-standard input.
 ------= ------------------------------------------------------------------------ Polarizable Continuum Model (PCM)
 =3D=3D=3D=3D=3D=3D=3D=3D= =3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=3D=
 Model          =       : C-PCM.
 Atomic radii  &n= bsp;      : UFF (Universal Force Field).
 = Polarization charges : Total charges.
 Charge compensation  : = None.
 Solution method      : On-the-fly s= election.
 Cavity type       &nb= sp;  : SAS (Solvent Accessible Surface) (Alpha=3D1.000).
 Cavi= ty algorithm     : GePol (No added spheres)
 &n= bsp;            = ;          Default sphere list= used, NSphG=3D   52.
      &nbs= p;            &= nbsp;    Lebedev-Laikov grids with approx.  5.0 points = / Ang**2.
          &n= bsp;            = ; Smoothing algorithm: Karplus/York (Gamma=3D1.0000).
   =             &nb= sp;        Polarization charges: spheric= al gaussians, with
         = ;            &n= bsp;            = ;            point-s= pecific exponents (IZeta=3D 3).
      &nbs= p;            &= nbsp;    Self-potential: point-specific (ISelfS=3D 7).
&n= bsp;            = ;           Self-field&nb= sp;   : sphere-specific E.n sum rule (ISelfD=3D 2).
 Solv= ent            =   : n,n-DiMethylFormamide, Eps=3D  37.219000 Eps(inf)=3D &nb= sp; 2.046330
          = ;            &n= bsp; RSolv=3D   2.647000 Ang.
 --------------------------= ----------------------------------------------------
 Warning! Inco= nsistent VMol and RSolv for this solvent, using VMol=3D   77.69 A= ng**3.
 No solvent atoms in DisRep.
 Error termination via = Lnk1e in /home/igors/g09/l301.exe at Wed May 24 20:48:59 2017.
 Job= cpu time:       0 days  0 hours  0= minutes  8.5 seconds.
 File lengths (MBytes):  RWF=3D&nb= sp;   610 Int=3D      0 D2E=3D &nbs= p;    0 Chk=3D     25 Scr=3D  =     1


If there is no manual definition
of RSolv, the following is printed:
With best regards,
Igors Mihailovs
ISSP UL

On 03/09/17 01:37, Zhiqiang Zhang zhangzq/./udel.edu wrote:<= /o:p>

<= pre>Sent to CCL by: "Zhiqiang=C2=A0 Zhang" [zhangzq{=3D}udel.edu]=
Hi all,
I am doing calculation with solvent and get th=
e error "No solvent atoms in DisRep" at the end. I am trying 
to include the dispersion and repulsion correction in my calculation=
=2E
My input file:
 
# opt() =
freq m062x/6-311G(2df,p) SCRF(CPCM, solvent=3DAceticAcid, read)
<=
o:p> 
Title Card Required
 <=
/pre>
0 1
 O=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=
=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0 0.00000000=C2=A0=C2=
=A0=C2=A0 0.00000000=C2=A0=C2=A0=C2=A0 0.11813800
 H=C2=A0=C2=A0=
=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=
=A0=C2=A0=C2=A0 0.00000000=C2=A0=C2=A0=C2=A0 0.75681000=C2=A0=C2=A0 -0.4725=
5200
 H=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=
=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0=C2=A0 0.00000000=C2=A0=C2=A0 -0.756=
81000=C2=A0=C2=A0 -0.47255200
 
dis
rep
cav
 
/*End of my =
input file*/
The last two lines of the log files:
No so=
lvent atoms in DisRep.
 Error termination via Lnk1e in /opt/share=
d/gaussian/g09d01/g09/l301.exe at Sat Sep=C2=A0 2 17:24:24 2017.
=
 
Does anybody know how to resolve this issue?
 

 




3D"Avast

This email has been checked for viruses by Avast antivirus software.
www.avast.com


=
--_5E5868C6-B423-46B7-8DD1-08A63F058AB3_--