From owner-chemistry@ccl.net Sat Jun 16 12:20:00 2012 From: "hope rs ryu dawnofnewhope/./yahoo.com.br" To: CCL Subject: CCL:G: gaussian 03w does not accept more than 1GB of memory in the calculatio Message-Id: <-47085-120615175745-10772-y85jtW8BuKrpqiQ2NGqXtg _ server.ccl.net> X-Original-From: "hope rs ryu" Date: Fri, 15 Jun 2012 17:57:44 -0400 Sent to CCL by: "hope rs ryu" [dawnofnewhope . yahoo.com.br] hi I have tried to do calculations in Gaussian 03 version C.01 (on windows) with greater than 1GB memory, but the calculation always gives error message 2070, and there is no error message in the output. I've tried on different machines i5 and i7 with windows XP and seven, but the error message continues. From owner-chemistry@ccl.net Sat Jun 16 13:25:00 2012 From: "Stephen P George spgeorge-#-ucsd.edu" To: CCL Subject: CCL:G: Gaussian ECP Message-Id: <-47086-120616125143-27628-BSd8U1Mt5/y4jspX7c3bew%server.ccl.net> X-Original-From: "Stephen P George" Date: Sat, 16 Jun 2012 12:51:42 -0400 Sent to CCL by: "Stephen P George" [spgeorge a ucsd.edu] Dear CCL members, I am trying to run a calculation on G03 with a Co metal center. I am using the SDD ECP but I wanted to add an f-polarization function to the ECP. However the syntax is giving me some trouble. I was hoping a member might make suggestions as to how to implement this. The inputs I have tried are shown below: %chk=PBE0SDD %NProcShared=8 # gen pbe1pbe pseudo=read Molecule Name Atom Description C 0 6-31G** **** H 0 6-31G** **** N 0 6-31G** **** Si 0 6-31G** **** Co 0 SDD F 1 1.00 0.1019000000D+01 0.1000000000D+01 **** Co 0 SDD and %chk=PBE0SDD %NProcShared=8 # gen pbe1pbe pseudo=read Molecule Name Atom Description C 0 6-31G** **** H 0 6-31G** **** N 0 6-31G** **** Si 0 6-31G** **** Co 0 SDD **** Co 0 SDD F 1 1.00 0.1019000000D+01 0.1000000000D+01 The first input file just seems to crash while the second gives me an error that stating there are no F atoms. Any help would be appreciated. Thanks, Stephen George From owner-chemistry@ccl.net Sat Jun 16 14:14:01 2012 From: "Kristin Gleason gleasonkristin__gmail.com" To: CCL Subject: CCL: Resonance Raman Message-Id: <-47087-120616025731-7314-0G/PWoo7ywEU8O9hfW+t9A() server.ccl.net> X-Original-From: Kristin Gleason Content-Type: multipart/alternative; boundary=e89a8f642d82ff8d2004c291716a Date: Sat, 16 Jun 2012 12:27:25 +0530 MIME-Version: 1.0 Sent to CCL by: Kristin Gleason [gleasonkristin++gmail.com] --e89a8f642d82ff8d2004c291716a Content-Type: text/plain; charset=ISO-8859-1 Hi , Can anybody tell how pre-resonance Raman and resonance Raman is different > from computational point of view? Also for fluorescence molecule can pre-resonance Raman will give satisfacory result? Thanks. --e89a8f642d82ff8d2004c291716a Content-Type: text/html; charset=ISO-8859-1
Hi ,
Can anybody tell how pre-resonance Raman and resonance Raman is different from computational point of view? Also for fluorescence molecule can pre-resonance Raman will give satisfacory result?
Thanks.
--e89a8f642d82ff8d2004c291716a--