From owner-chemistry@ccl.net Mon Jun 4 05:27:01 2007 From: "Thomas Joseph alabarae+/-yahoo.com" To: CCL Subject: CCL: fragment filtering Message-Id: <-34405-070604051029-32739-/gIB04YMCBgb1IIBmESwiA-#-server.ccl.net> X-Original-From: "Thomas Joseph" Date: Mon, 4 Jun 2007 05:10:24 -0400 Sent to CCL by: "Thomas Joseph" [alabarae..yahoo.com] Hi all, Do any of you know about any FREE softwares which can identify fragments in a chemical database that wil run under Windows? I want to identify specific fragments in a chemical database thank you in advance From owner-chemistry@ccl.net Mon Jun 4 08:27:00 2007 From: "Szabolcs Csepregi scsepregi ~~ chemaxon.com" To: CCL Subject: CCL: fragment filtering Message-Id: <-34406-070604082429-6244-96WeYYwiG8S+wmNZyZnczw|,|server.ccl.net> X-Original-From: Szabolcs Csepregi Content-Transfer-Encoding: 7bit Content-Type: text/plain; charset=UTF-8; format=flowed Date: Mon, 04 Jun 2007 13:28:23 +0200 MIME-Version: 1.0 Sent to CCL by: Szabolcs Csepregi [scsepregi*|*chemaxon.com] Hi, Have a look at Instant JChem: http://www.chemaxon.com/product/ijc.html Regards, Szabolcs Szabolcs Csepregi, PhD Director of Search Technologies, ChemAxon Ltd. http://www.chemaxon.com Skype: szabolcs.csepregi Tel: +36 1 3878564 Cell: +36 20 4219863 Fax: +36 1 4532659 Thomas Joseph alabarae+/-yahoo.com wrote: > Sent to CCL by: "Thomas Joseph" [alabarae..yahoo.com] > Hi all, > > Do any of you know about any FREE softwares which can identify fragments in a chemical database that wil run under Windows? > I want to identify specific fragments in a chemical database > > thank you in advance> > > > > From owner-chemistry@ccl.net Mon Jun 4 09:02:00 2007 From: "Mingyue Zheng myzheng ~ gmail.com" To: CCL Subject: CCL: fragment filtering Message-Id: <-34407-070604082303-6182-IvxeRX2QB0zTrKllGqyAwg|*|server.ccl.net> X-Original-From: "Mingyue Zheng" Content-Type: multipart/alternative; boundary="----=_Part_285_7602566.1180956502384" Date: Mon, 4 Jun 2007 19:28:22 +0800 MIME-Version: 1.0 Sent to CCL by: "Mingyue Zheng" [myzheng++gmail.com] ------=_Part_285_7602566.1180956502384 Content-Type: text/plain; charset=ISO-8859-1; format=flowed Content-Transfer-Encoding: 7bit Content-Disposition: inline you may try openbabel, good luck! 2007/6/4, Thomas Joseph alabarae+/-yahoo.com : > > > Sent to CCL by: "Thomas Joseph" [alabarae..yahoo.com] > Hi all, > > Do any of you know about any FREE softwares which can identify fragments > in a chemical database that wil run under Windows? > I want to identify specific fragments in a chemical database > > thank you in advance> > > > -- -------------------------------------------------------------------------------- Dr. Mingyue Zheng Research Associate, Drug Discovery and Design Center (DDDC) Box 1201, Shanghai Institute of Materia Medica. 555 Rd. Zuchongzhi, Shanghai, China Tel: 86-021-50806600-1201 Web: http://dddc.ac.cn Email: myzheng-$-mail.shcnc.ac.cn ------=_Part_285_7602566.1180956502384 Content-Type: text/html; charset=ISO-8859-1 Content-Transfer-Encoding: 7bit Content-Disposition: inline you may try openbabel, good luck!

2007/6/4, Thomas Joseph alabarae+/-yahoo.com <owner-chemistry-$-ccl.net>:

Sent to CCL by: "Thomas  Joseph" [alabarae..yahoo.com]
Hi all,

Do any of you know about any FREE softwares which can identify fragments in a chemical database that wil run under Windows?
I want to identify specific fragments in a chemical database

thank you in advance



E-mail to subscribers: CHEMISTRY-$-ccl.net or use:
     http://www.ccl.net/cgi-bin/ccl/send_ccl_message

E-mail to administrators: CHEMISTRY-REQUEST-$-ccl.net or use
     http://www.ccl.net/cgi-bin/ccl/send_ccl_message

Subscribe/Unsubscribe:
     http://www.ccl.net/chemistry/sub_unsub.shtml

Before posting, check wait time at: http://www.ccl.net

Job: http://www.ccl.net/jobs
Conferences: http://server.ccl.net/chemistry/announcements/conferences/

Search Messages: http://www.ccl.net/htdig  (login: ccl, Password: search)
     http://www.ccl.net/spammers.txt

RTFI: http://www.ccl.net/chemistry/aboutccl/instructions/






--
--------------------------------------------------------------------------------
Dr. Mingyue Zheng
Research Associate, Drug Discovery and Design Center (DDDC)
Box 1201, Shanghai Institute of Materia Medica.
555 Rd. Zuchongzhi, Shanghai, China
Tel:      86-021-50806600-1201
Web:   http://dddc.ac.cn
Email: myzheng-$-mail.shcnc.ac.cn ------=_Part_285_7602566.1180956502384-- From owner-chemistry@ccl.net Mon Jun 4 09:58:00 2007 From: "Shobe, David David.Shobe]~[sud-chemie.com" To: CCL Subject: CCL:G: AIM information Message-Id: <-34408-070604095701-22774-HdX8MIWNneCoXK+O0thGxA:_:server.ccl.net> X-Original-From: "Shobe, David" Content-class: urn:content-classes:message Content-Transfer-Encoding: 8bit Content-Type: text/plain; charset="us-ascii" Date: Mon, 4 Jun 2007 15:56:10 +0200 MIME-Version: 1.0 Sent to CCL by: "Shobe, David" [David.Shobe- -sud-chemie.com] I've had difficulties with AIM2000 where symmetry-equivalent atoms had different charges, etc. Using "nosymm" in the Gaussian calculation to prevent re-orientation of the coordinates resolved that problem. (And I got the idea to use "nosymm" from the CCL list! :-) --David Shobe -----Original Message----- > From: owner-chemistry . ccl.net [mailto:owner-chemistry . ccl.net] Sent: Friday, June 01, 2007 5:11 PM To: Shobe, David Subject: CCL:G: AIM information Sent to CCL by: "Guermoune Abdeladim" [lguermoune]|[hotmail.com] Hello, I am beginner with the program of AIM2000 analysis. First I have create file wfn from the Gaussian98 using words key P B3LYP/6-311+G** output=wfn density=current, then I treated file wfn by the AIM2000 program to localize the critical points, the density and laplacian. But the results don't seem to me coherent, for example when the density increases laplacian can take a positive value, and it can take a negative value when the density decrease. In my structure I have specially a metallic center: iron, and two borons with hydrogens in bridged position. I wish to know if there is another manner to improve my file result wfn or any others suggestions. Thanks.http://www.ccl.net/cgi-bin/ccl/send_ccl_messagehttp://www.ccl.net/chemistry/sub_unsub.shtmlhttp://www.ccl.net/spammers.txtThis e-mail message may contain confidential and / or privileged information. If you are not an addressee or otherwise authorized to receive this message, you should not use, copy, disclose or take any action based on this e-mail or any information contained in the message. If you have received this material in error, please advise the sender immediately by reply e-mail and delete this message. Thank you. From owner-chemistry@ccl.net Mon Jun 4 10:35:00 2007 From: "Dr. Ponnadurai Ramasami ramchemi#,#intnet.mu" To: CCL Subject: CCL: statistical weight Message-Id: <-34409-070604073241-3176-sJYDay9mv51tSsD60s6f3Q _ server.ccl.net> X-Original-From: "Dr. Ponnadurai Ramasami" Content-Type: multipart/alternative; boundary="----=_NextPart_000_0013_01C7A6B6.B818A4F0" Date: Mon, 4 Jun 2007 14:43:30 +0400 MIME-Version: 1.0 Sent to CCL by: "Dr. Ponnadurai Ramasami" [ramchemi%x%intnet.mu] This is a multi-part message in MIME format. ------=_NextPart_000_0013_01C7A6B6.B818A4F0 Content-Type: text/plain; charset="Windows-1252" Content-Transfer-Encoding: quoted-printable Dear ALL I have considered the gauche and trans conformers of = 1,2-diisocyanoethane. I have calculated the equilibrium constant from the free energy = difference between these two forms. Then from the equilibrium constant, I have deduced the percentage of = each conformer. However one reviewer pointed out that "Statistical weight of the gauche rotamers (R ln2) was excluded when the = author estimate the percentage of trans rotamers" I believe that my method is ok Can anyone suggest how to include the statistical weight? Thanks Ramasami ------=_NextPart_000_0013_01C7A6B6.B818A4F0 Content-Type: text/html; charset="Windows-1252" Content-Transfer-Encoding: quoted-printable
Dear ALL
I have considered the gauche and trans conformers of=20 1,2-diisocyanoethane.
I have calculated the equilibrium constant from the free energy = difference=20 between these two forms.
Then from the equilibrium constant, I have deduced the percentage = of each=20 conformer.
 
However one reviewer pointed out that
"Statistical weight of the gauche rotamers (R ln2) was excluded = when the=20 author estimate the percentage of trans rotamers"
I believe that my method is ok
 
Can anyone suggest how to include the = statistical=20 weight?
Thanks
Ramasami
 
 
------=_NextPart_000_0013_01C7A6B6.B818A4F0-- From owner-chemistry@ccl.net Mon Jun 4 14:01:00 2007 From: "Yingbin Ge yingbin.ge- -gmail.com" To: CCL Subject: CCL: statistical weight Message-Id: <-34410-070604135942-23048-feDgUzJ38M+Qydrk7CresQ(-)server.ccl.net> X-Original-From: "Yingbin Ge" Content-Disposition: inline Content-Transfer-Encoding: 7bit Content-Type: text/plain; charset=ISO-8859-1; format=flowed Date: Mon, 4 Jun 2007 12:59:36 -0500 MIME-Version: 1.0 Sent to CCL by: "Yingbin Ge" [yingbin.ge,+,gmail.com] I think the author meant that there were 2 degenerate gauche conformations (and only 1 trans conformation) and probably you might not have considered the degeneracy factor? Yingbin On 6/4/07, Dr. Ponnadurai Ramasami ramchemi#,#intnet.mu wrote: > > > Dear ALL > I have considered the gauche and trans conformers of 1,2-diisocyanoethane. > I have calculated the equilibrium constant from the free energy difference > between these two forms. > Then from the equilibrium constant, I have deduced the percentage of each > conformer. > > However one reviewer pointed out that > "Statistical weight of the gauche rotamers (R ln2) was excluded when the > author estimate the percentage of trans rotamers" > I believe that my method is ok > > Can anyone suggest how to include the statistical weight? > Thanks > Ramasami > > -- Yingbin Ge, Ph. D. 207 Spedding Hall, Ames Lab, Iowa State University Ames, IA 50011 (Office Phone: 515-294-0540) From owner-chemistry@ccl.net Mon Jun 4 14:43:00 2007 From: "Grigoriy Zhurko reg_zhurko ~~ chemcraftprog.com" To: CCL Subject: CCL: Gaussian/PCM/chemical shifts Message-Id: <-34411-070604125800-17211-Rxiz1FCJZOEgmbCqW6mPKQ%server.ccl.net> X-Original-From: Grigoriy Zhurko Content-Transfer-Encoding: 8bit Content-Type: text/plain; charset=iso-8859-1 Date: Mon, 4 Jun 2007 20:58:55 -0700 MIME-Version: 1.0 Sent to CCL by: Grigoriy Zhurko [reg_zhurko]![chemcraftprog.com] I suppose, using the calculated TMS carbon shielding is not correct enough, because the TMS standard used in the experiment is not in the gas phase. I tried to calculate the TMS shielding at same level of theory as investigated molecules, but their chemical shifts with it were still overestimated. > Dear Grigoriy Zhurko, > in [1] we discuss the importance of the TMS 13C reference values. > Please find a paragraph which might be relevant to your message > cited below: > [..] > Particular attention should be paid to the case of > TMS. For this reference compound in proton and > carbon-13 NMR, two structures of Td symmetry exist, > as illustrated in ¨gure 1. The one in ¨gure 1 (a) is the > global minimum, and the structure of ¨gure 1 (b) is a > fourth-order saddle point. The energy of the global > minimum (¨gure 1 (a)) , taken from the B3LYP calcula- > tion, is 27. 3 kJ molÁ1 lower than the one for structure > (b). The corresponding absolute shielding value for 13 C > is 200.3 ppm. We chose this value as the reference chemi- > cal shift as it corresponds to a true minimum structure. > Cheeseman et al. [49] report a 13 C chemical shielding of > 195.1 ppm for TMS, whereas our calculation for the > non-minimum structure of ¨gure 1 (b) reproduced a > value of 195.4 ppm. > [..] > There is a little more discussion in the paper. > Regards, > Marc Baaden > [1] M. Baaden, P. Granger and A. Strich; "Dependence of isotropic > shift averages and nuclear shielding tensors on the internal > rotation of the functional group X about the C-X bond in seven > simple vinylic derivatives H2C=CH-X.", Mol. Phys., 98, 2000, > 329-342. >>>> "Grigoriy Zhurko reg_zhurko(!)chemcraftprog.com" said: >>> >>> Sent to CCL by: Grigoriy Zhurko [reg_zhurko]*[chemcraftprog.com] >>> This problem is interesting for me too. I have found that computed gas-ph > ase 13C chemical shifts (GIAO B3LYP/6-311G(D,P)) correlate very well with > the experiment (in CCl4), but the computed values of chemical shifts are s > ignificantly overestimated. Maybe the problem is in the reference value fo > r converting isotropic shielding into chemical shifts (e.g. with TMS). Wha > t value of the TMS shielding on carbon should be used? Sincerely, Grigoriy Zhurko. From owner-chemistry@ccl.net Mon Jun 4 15:36:00 2007 From: "Reynier Suardiaz reynier.suardiaz!^!gmail.com" To: CCL Subject: CCL:G: EPR-II, III contraction coefficients Message-Id: <-34412-070604152635-3883-dV52eDtOJryM05l2RRF0Xw(0)server.ccl.net> X-Original-From: "Reynier Suardiaz" Date: Mon, 4 Jun 2007 15:26:30 -0400 Sent to CCL by: "Reynier Suardiaz" [reynier.suardiaz(a)gmail.com] Dear CCLers I need the complete set of contraction coefficients for EPR-II and EPR-III basis sets. If it is possible, in Gaussian format. Thanks in advance Reynier -- http://rincon.uam.es/dir?cw=331069946289062 From owner-chemistry@ccl.net Mon Jun 4 16:11:00 2007 From: "=?ISO-8859-1?Q?Reynier_Suardiaz_del_R=EDo?= reynier.suardiaz.(-).uam.es" To: CCL Subject: CCL:G: EPR-II, III contraction coefficients Message-Id: <-34413-070604145034-18416-NH0LBnK5uxEEXkmyJeBTqg(-)server.ccl.net> X-Original-From: "=?ISO-8859-1?Q?Reynier_Suardiaz_del_R=EDo?=" Content-Disposition: inline Content-Transfer-Encoding: 7bit Content-Type: text/plain; charset=ISO-8859-1; format=flowed Date: Mon, 4 Jun 2007 17:15:51 +0000 MIME-Version: 1.0 Sent to CCL by: "=?ISO-8859-1?Q?Reynier_Suardiaz_del_R=EDo?=" [reynier.suardiaz_._uam.es] Dear CCLers I need the complete set of contraction coefficients for EPR-II and EPR-III basis sets. If it is possible, in Gaussian format. Thanks in advance Reynier -- http://rincon.uam.es/dir?cw=331069946289062 From owner-chemistry@ccl.net Mon Jun 4 20:15:00 2007 From: "Mustafa Hussein mustafa.hussein86]|[yahoo.com" To: CCL Subject: CCL: Running GAMESS on Intel Celeron Processors Message-Id: <-34414-070604201154-17922-SUS4YwTzjYDAT42n+ksySQ^^server.ccl.net> X-Original-From: "Mustafa Hussein" Date: Mon, 4 Jun 2007 20:11:51 -0400 Sent to CCL by: "Mustafa Hussein" [mustafa.hussein86%%yahoo.com] Hi, My PC has an Intel Celeron Processor. I have checked the specifications on hardware requirements for running GAMESS. I found no thing stated on Celeron Processors. Does this mean GAMESS can not be run on such processors? If so, I am gonna change my processor, really. Any help is appreciated Thanks Mustafa From owner-chemistry@ccl.net Mon Jun 4 23:58:00 2007 From: "Senthil Nathan zenthil03:+:yahoo.co.in" To: CCL Subject: CCL: Iodide ion optimaization Message-Id: <-34415-070604235446-26263-4tjI+jegi7Mpd9mm7q3Taw ~~ server.ccl.net> X-Original-From: "Senthil Nathan" Date: Mon, 4 Jun 2007 23:54:43 -0400 Sent to CCL by: "Senthil Nathan" [zenthil03^-^yahoo.co.in] Dear CCLers I have used Iodide ion as a nucleophile in my organic reaction. i want to optimaize this ion. please you tell me a best basis setlevel for this Iodide ion optimaization and energy calculation for DFT level. regards by senthil